We have been making heat-transfer components since 2009 in Foshan. Four product lines share one workshop: coaxial exchangers, tank exchangers, suction accumulators and receivers — plus the common refrigeration fittings that go with them.
Talk to salesCopper and steel tubes are cut and formed to the drawing; the ends are prepared before assembly.
Both connections are brazed with a flame and filler metal, then inspected one by one. We do not TIG-weld these joints.
Refrigerant side and water side are pressurised separately and held to check for any pressure drop.
The assembled unit is submerged; a continuous stream of bubbles means a reject.
| We can | Sample in 1 day for standard sizes; stock sizes ship immediately; 3–10 days for custom units; pressure and leak test records with the shipment; build to drawing or reverse-engineer from a sample part. |
|---|---|
| We cannot | Guarantee a specific service life — it depends on water quality, duty cycle and maintenance. We also cannot guarantee against scaling where water is hard; a water treatment unit is the practical fix. |
PDF or CAD, with overall length, connection diameter and mounting hole spacing.
Photos of both faces and the side, with a ruler in frame.
Capacity in HP, refrigerant type, heating-only or reverse-cycle, water quality.
Expected quantity per order and per year, so we can quote realistically.
Send the drawing or sample photos and we will reply with specification, lead time and price.