In a reverse-cycle heat pump the refrigerant flows the other way in heating mode. A single-direction receiver can stop doing its job; a bidirectional receiver stores and returns liquid in both modes.
Request a quote
| Application | Reverse-cycle heat pumps, combined heating/cooling units |
|---|---|
| Flow path | Bidirectional — stores and returns liquid in both modes |
| Volume | Matched to system refrigerant charge |
| Reference size (5 HP) | 1.8 L effective volume, 115 mm shell diameter, 265 mm height, 12.7 mm connection ID |
| Connections | Position and diameter to customer requirement |
| Sample lead time | 1 day for standard sizes |
| Testing | Pressure test + immersion leak test |
Heating mode reverses the flow; a single-direction unit may not store liquid at all.
Internal arrangement keeps oil moving back to the compressor.
Sized from refrigerant charge and water volume, not guessed from HP alone.
Reduces on-site re-piping and re-testing.
Not recommended. In heating mode the flow reverses and the receiver may no longer store liquid properly.
From the system refrigerant charge and water-side volume. Send the charge and we will suggest a size.
Yes — send connection diameters, orientation and available space.
Tell us refrigerant charge and connection sizes and we will size the receiver.